Products
AAC All Aluminum Conductor

AAC All Aluminum Conductor

This all aluminum conductor is a kind of aluminum product made through stranding aluminum wires. It is used for the electricity distribution lines with short span length and small load-carrying capability of the pole. The AAC provides reliable performance for overhead power transmission and distribution lines. This standard covers hard drawn circular aluminum wires for electric purposes to be used as component wires of hard drawn aluminum stranded cables and aluminum conductor steel reinforced.

Construction

AAC is a concentric-lay-stranded conductor consisting of aluminum alloy 1350-H19 wires available in both single-layer and multi-layer constructions.

Standards

ASTM B 231/B 231M CSA C49,BS 215 Part 1, IEC 61089, DIN 48201, JIS C 3109,AS/NZS 1531-91,GOST 839-80

 

ASTM B 231/B 231M CSA C49

Code name

Area

Stranding /wire Dia.

Approox. Overall Dia.

Weight

Nominal breaking load

Nom. DC resistance at 20 deg.

Nominal

Actual

AWG or MCM

mm²

mm

mm

kg/km

kN

ohm/km

PEACHBELL

6

13.29

7/1.554

4.67

37

2.49

2.1692

ROSE

4

21.16

7/1.961

5.89

58

3.96

1.3624

IRIS

2

33.61

7/2.474

7.42

93

5.97

0.8577

PANSY

1

42.39

7/2.776

8.33

117

7.32

0.6801

POPPY

1/0

53.48

7/3.119

9.36

147

8.73

0.539

ASTER

2/0

67.42

7/3.503

10.51

186

11.00

0.4276

PHLOX

3/0

85.03

7/3.932

11.80

234

13.47

0.339

OXLIP

4/0

107.23

7/4.417

13.26

296

16.98

0.2688

VALERIAN

250

126.71

19/2.913

14.57

349

20.62

0.2275

SNEEZEWORT

250

126.71

7/4.80

14.40

349

20.07

0.2275

LAUREL

266.8

135.16

19/3.01

15.05

373

22.00

0.2133

DAISY

266.8

135.16

7/4.96

14.90

373

21.41

0.2133

PEONY

300

152.0

19/3.193

15.97

419

24.03

0.1896

TULIP

336.4

170.45

19/3.381

16.91

470

26.95

0.1691

DAFFODIL

350

177.35

19/3.447

17.24

489

28.04

0.1625

CANNA

397.5

201.42

19/3.673

18.36

555

31.84

0.1431

GOLDENTUFT

450

228.0

19/3.909

19.55

629

34.99

0.1264

SYRINGA

477

241.68

37/2.882

20.19

666

38.49

0.1193

COSMOS

477

241.68

19/4.023

20.12

666

37.08

0.1193

HYACINTH

500

253.35

37/2.951

20.65

698

40.35

0.1138

ZINNIA

500

253.35

19/4.12

20.60

698

38.88

0.1138

DAHLIA

556.5

282

19/4.346

21.73

777

43.27

0.1022

MISTLETOE

556.5

282

37/3.114

21.79

777

43.62

0.1022

MEADOWSWEET

600

304

37/3.233

22.63

838

47.03

0.0948

ORCHID

636

322.25

37/3.33

23.31

888

49.85

0.0894

HEUCHERA

650

329.35

37/3.366

23.56

908

50.95

0.0875

FLAG

700

354.71

61/2.72

24.48

978

51.46

0.0813

VERBENA

700

354.71

37/3.493

24.45

978

54.87

0.0813

NASTURTIUM

715.5

362.58

61/2.75

24.76

1000

58.74

0.0795

VIOLET

715.5

362.58

37/3.533

24.74

1000

56.09

0.0795

CATTAIL

750

380

61/2.817

25.35

1048

59.85

0.0759

PETUNIA

750

380

37/3.617

25.32

1048

58.75

0.0759

LILAC

795

402.84

61/2.90

26.11

1111

63.45

0.0715

ARBUTUS

795

402.84

37/3.724

26.06

1111

62.32

0.0715

SNAPDRAGON

900

456.06

61/3.086

27.78

1257

69.78

0.0632

COCKSCOMB

900

456.06

37/3.962

27.73

1257

68.48

0.0632

GOLDENROD

954

483.42

61/3.177

28.60

1333

78.96

0.0596

MAGNOLIA

954

483.42

37/4.079

28.55

1333

72.58

0.0596

CAMELLIA

1000

506.71

61/3.251

29.36

1397

77.53

0.0569

HAWKWEED

1000

506.71

37/4.176

29.23

1397

76.08

0.0569

LARKSPUR

1033.5

523.68

61/3.307

29.76

1444

80.12

0.055

BLUEBELL

1033.5

523.68

37/4.244

29.72

1444

78.63

0.055

MARIGOLD

1113

563.93

61/3.432

30.89

1555

86.28

0.0511

HAWTHORN

1192.5

604.26

61/3.551

31.05

1666

92.45

0.0477

NARCISSUS

1272

644.51

61/3.668

33.02

1777

98.61

0.0447

COLUMBINE

1351.5

684.84

61/3.78

34.01

1888

104.78

0.0421

CARNATION

1431

725.1

61/3.89

35.03

1999

107.68

0.0398

GLADIOLUS

1510.5

765.35

61/4.00

35.09

2110

113.65

0.0376

COREOPSIS

1590

805.68

61/4.099

36.51

2221

119.64

0.0358

JESSAMINE

1750

886.71

61/4.302

38.72

2445

131.68

0.0325

COWSLIP

2000

1013.42

91/3.76

41.4

2791

15.3

0.0285

LUPINE

2500

1266.67

91/4.21

46.3

3524

18.7

0.023

TRILLIUM

3000

1520.13

127/3.90

50.75

4232

22.5

0.0192

BLUEBONNET

3500

1773.5

127/4.21

54.8

4985

26.2

0.0166

BS 215 Part 1

Code Name

Area

Stranding and wire diameter

Approx. Overall diameter

Weight

Nominal breaking load

Nom. DC resistance at 20 deg.

Nominal

Actual

mm²

mm²

mm

mm

kg/km

kN

ohm/km

MIDGE

22

23.33

7/2.06

6.2

64

3.99

1.227

APHIS

25

26.4

3/3.35

7.2

73

4.11

1.081

GNAT

25

26.8

7/2.21

6.6

73

4.59

1.066

WEEVIL

30

31.6

3/3.66

7.9

86

4.86

0.9082

MOSQUITO

35

37.0

7/2.59

7.8

101

6.03

0.7762

LADYBIRD

40

42.8

7/2.79

8.4

117

6.87

0.6689

ANT

50

52.83

7/3.10

9.3

145

8.28

0.5419

FLY

60

63.55

7/3.40

10.2

174

9.90

0.4505

BLUEBOTTLE

70

73.7

7/3.66

11.0

202

11.34

0.3881

EARWING

75

78.5

7/3.78

11.4

215

11.94

0.3644

GRASSHOPPER

80

84.1

7/3.91

11.7

230

12.78

0.3406

CLEGG

90

95.6

7/4.17

12.5

262

14.53

0.2994

WASP

100

106.0

7/4.39

13.2

290

16.00

0.2702

BEETLE

100

106.6

19/2.67

13.4

293

17.42

0.2704

BEE

125

132.0

7/4.90

14.7

361

19.44

0.2169

CRICKET

150

157.9

7/5.36

16.1

432

23.85

0.1818

HORNET

150

157.6

19/3.25

16.3

434

25.70

0.1825

CATERPILLAR

175

186.0

19/3.53

17.7

512

28.63

0.1547

CHAFER

200

213.2

19/3.78

18.9

587

32.40

0.1349

SPIDER

225

236.9

19/3.99

20.0

652

36.01

0.1211

COCKROACH

250

265.7

19/4.22

21.1

731

40.40

0.1083

BUTTERFLY

300

322.7

19/4.65

23.3

888

48.70

0.08916

MOTH

350

373.2

19/5.00

25.0

1027

56.37

0.07711

DRONE

350

373.3

37/3.58

25.1

1029

57.45

0.07741

LOCUST

400

428.5

19/5.36

26.8

1179

64.73

0.06710

CENTIPEDE

400

415.2

37/3.78

26.5

1145

63.10

0.06944

MAYBUG

450

486.9

37/4.09

28.6

1342

74.01

0.05931

SCORPION

500

529.5

37/4.27

29.9

1460

79.98

0.05441

CICADA

600

628.6

37/4.65

32.6

1733

94.95

0.04588

TARANTULA

750

794.6

37/5.23

36.6

2191

120.10

0.03627

IEC 61089

Code name

Area

Stranding and wire diameter

Approox. Overall diameter

Weight

Nominal breaking load

Nom. DC resistance at 20 deg.

Nominal

Actual

mm²

mm²

mm

mm

kg/km

kN

ohm/km

10

10

7

1.35

4.05

27.4

1.95

2.8633

16

16

7

1.71

5.12

43.8

3.04

1.7896

25

25

7

2.13

6.40

68.4

4.50

1.1453

40

40

7

2.70

8.09

109.4

6.80

0.7158

63

63

7

3.39

10.2

172.3

10.39

0.4545

100

100

19

2.59

12.9

274.8

17.00

0.2877

125

125

19

2.89

14.5

343.6

21.25

0.2302

160

160

19

3.27

16.4

439.8

26.40

0.1798

200

200

19

3.66

18.3

549.7

32.00

0.1439

250

250

19

4.09

20.5

687.1

40.00

0.1151

315

315

37

3.29

23.0

867.9

51.97

0.0916

400

400

37

3.71

26.0

1102.0

64.00

0.0721

450

450

37

3.94

27.5

1239.8

72.00

0.0641

500

500

37

4.15

29.0

1377.6

80.00

0.0577

560

560

37

4.39

30.7

1542.9

89.60

0.0515

630

630

61

3.63

32.6

1738.3

100.80

0.0458

710

710

61

3.85

34.6

1959.1

113.60

0.0407

800

800

61

4.09

36.8

2207.4

128.00

0.0361

900

900

61

4.33

39.0

2483.3

144.00

0.0321

1000

1000

61

4.57

41.1

2759.2

160.00

0.0289

1120

1120

91

3.96

43.5

3093.5

179.20

0.0258

1250

1250

91

4.18

46.0

3452.6

200.00

0.0231

1400

1400

91

4.43

48.7

3866.9

224.00

0.0207

1500

1500

91

4.58

50.4

4143.1

240.00

0.0193

DIN 48201

Code No.

Calculated Area

No.of Wires

Diameter

Overall Dia.

Liner Mass

Calculated Breaking Load

Max. D.C. Resistance at 20 degree

No.

sq.mm

 

mm

mm

kg/km

daN

Ohm/km

16

15.89

7

1.70

5.1

44

290

1.80

25

24.25

7

2.10

6.3

67

425

1.18

35

34.36

7

2.50

7.5

94

585

0.83

50

49.48

7

3.00

9

135

810

0.58

50

48.36

19

1.80

9

133

860

0.60

70

65.82

19

2.10

10.5

181

1150

0.44

95

93.27

19

2.50

12.5

256

1595

0.31

120

117.0

19

2.80

14

322

1910

0.25

150

147.1

37

2.25

15.2

406

2570

0.20

185

181.6

37

2.50

17.5

501

3105

0.16

240

242.54

61

2.25

20.2

670

4015

0.12

300

299.43

61

2.50

22.5

827

4850

0.10

400

400.14

61

2.89

26

1105

6190

0.07

500

499.83

61

3.23

29.1

1381

7600

0.06

625

626.2

91

2.96

32.6

1733

9690

0.05

800

802.1

91

3.35

36.8

2219

12055

0.04

1000

999.71

91

3.74

41.1

2766

14845

0.03

AS/NZS 1531-91

Conductor codename

Stranding and wire diameter

Nominal overall diameter

Cross- sectional area

Approximate mass

Breaking load

Modulus of elasticity

Coefficient of linear expansion

DC resist. at 20°C

AC resist. at 50Hz

 

no/mm

mm

mm2

kg/km

kN

GPa

x 10–6/°C

Ω/km

Ω/km

Leo

7/2.50

7.5

34.4

94.3

5.71

65

23

0.833

1.02

Leonids

7/2.75

8.25

41.6

113

6.72

65

23

0.689

0.842

Libra

7/3.00

9

49.5

135

7.98

65

23

0.579

0.707

Mars

7/3.75

11.3

77.3

211

11.8

65

23

0.37

0.452

Mercury

7/4.50

13.5

111

304

16.9

65

23

0.258

0.315

Moon

7/4.75

14.3

124

339

18.9

65

23

0.232

0.284

Neptune

19/3.25

16.3

158

433

24.7

65

23

0.183

0.224

Orion

19/3.50

17.5

183

503

28.7

65

23

0.157

0.192

Pluto

19/3.75

18.8

210

576

31.9

65

23

0.137

0.168

Saturn

37/3.00

21

262

721

42.2

64

23

0.11

0.135

Sirius

37/3.25

22.8

307

845

48.2

64

23

0.094

0.116

Taurus

19/4.75

23.8

337

924

51.3

65

23

0.0857

0.105

Triton

37/3.75

26.3

409

1120

62.2

64

23

0.0706

0.0872

Uranus

61/3.25

29.3

506

1400

75.2

64

23

0.0572

0.071

Ursula

61/3.50

31.5

587

1620

87.3

64

23

0.0493

0.0616

Venus

61/3.75

33.8

673

1860

97.2

64

23

0.0429

0.0539

GOST 839-80

Nominal Corss-section

Number of Wires

Wire Diameter

Calculated Cross-section

Overall Diameter

D.C. Resistance at 20

Min. Breaking Load

Conductor Weight

Grease Weight

mm2

 

mm

mm2

mm

Ω/km

 

kg/km

kg/km

10

7

1,35

10,0

4,05

2,8631

1950

27,4

16

7

1,70

15,9

5,10

1,8007

3021

43,0

0,5

25

7

2,13

24,9

6,40

1,1498

4500

68,0

0,5

35

7

2,50

34,3

7,50

0,8347

5913

94,0

0,5

40

7

2,70

40,0

8,09

0,7157

6800

109,4

50

7

3,00

49,5

9,00

0,5784

8198

135,0

0,5

63

7

3,39

63,0

10,16

0,4544

10390

172,3

70

7

3,55

69,3

10,70

0,4131

11288

189,0

1,0

95

7

4,10

92,4

12,30

0,3114

14784

252,0

1,0

100

19

2,59

100,0

12,94

0,2877

17000

274,9

120

19

2,80

117,0

14,00

0,2459

19890

321,0

16

125

19

2,89

125,0

14,47

0,2301

21250

343,6

150

19

3,15

148,0

15,80

0,1944

24420

406,0

20

160

19

3,27

160,0

16,37

0,1798

26400

439,8

185

19

3,50

182,8

17,50

0,1574

29832

502,0

25

200

19

3,66

200,0

18,30

0,1438

32000

549,7

240

19

4,00

238,7

20,00

0,1205

38192

655,0

33

250

19

4,09

250,0

20,47

0,1150

40000

687,1

300

37

3,15

288,3

22,10

0,1000

47569

794,0

54

315

37

3,29

315,0

23,05

0,0915

51970

867,5

350

37

3,45

345,8

24,20

0,0833

57057

952,0

65

400

37

3,66

389,2

25,60

0,0740

63420

1072,0

73

450

37

3,90

449,1

27,30

0,0642

71856

1206,0

84

500

37

4,15

500,4

29,10

0,0576

80000

1378,0

94

550

61

3,37

544,0

30,30

0,0529

89760

1500,0

117

560

37

4,39

560,0

30,73

0,0531

89600

1542,2

600

61

3,50

586,8

31,50

0,0491

95632

1618,0

126

630

61

3,63

630,0

32,64

0,0458

100800

1738,4

650

61

3,66

641,7

32,90

0,0450

104575

1771,0

138

700

61

3,80

691,7

34,20

0,0417

112725

1902,0

149

710

61

3,85

710,0

34,65

0,0406

113600

1959,2

750

61

3,95

747,4

35,60

0,0386

119584

2062,0

161

JIS C 3109

Nominal area (mm²)

Construction, No./Wire diameter (No./mm)

Calculated area (mm²)

Approx. overall diameter (mm)

Standard weight (Kg/Km)

Minimum breaking load (Kgf)

Calculated DC resistance at 20°C (Ohm/Km)

Hard-drawn copper equivalent area (mm²)

30

7/2.3

29.1

6.9

79.5

469

0.983

18.3

38

7/2.6

37.2

7.8

102

575

0.769

23.4

55

7/3.2

56.3

9.6

154

838

0.507

35.4

95

7/4.2

97.0

12.6

265

1410

0.295

61.0

150

19/3.2

153

16.0

419

2270

0.188

96.2

200

19/3.7

204

18.5

560

3030

0.140

128

240

19/4.0

239

20.0

655

3490

0.120

150

300

37/3.2

298

22.4

820

4430

0.0969

187

400

37/3.7

398

25.9

1097

5890

0.0726

250

510

37/4.2

513

29.4

1413

7460

0.0563

323

660

61/3.7

656

33.3

1812

9720

0.0441

412

850

61/4.2

845

37.8

2334

12300

0.0342

531

980

91/3.7

978

40.7

2716

14500

0.0297

615

1260

91/4.2

1261

46.2

3499

18350

0.0230

793

Related Products

Inquiry

Please Feel free to give your inquiry in the form below.we will reply you in 24 hours.

    • *

    • *

    • *

    Home Tel Mail Inquiry